Geekcreit Assembled Geiger Counter Module Miller Tube GM Tube Nuclear Radiation Geekcreit for Arduino - products that work with official Arduino boards
* Estimated delivery times start from the date of shipment, excluding processing time.
* Actual delivery times may vary due to holidays, weather conditions, or customs delays.
Return items will be accepted within 40 days when is the date of receiving the goods. Customized items cannot be returned or exchanged. Items bought with an e-gift card are exchangeable only; refunds are not applicable.
Free Gift
Welcome to Roymall, your professional website for purchasing premium department store gifts. We highly value and appreciate your support, and we want to express our gratitude by adding an extra touch of excitement to your purchases. When you shop with us, you not only get to enjoy high-quality products that enhance your lifestyle, but you'll also receive an exclusive free gift with every order you place. Ready to explore our collection and find your perfect gifts? Browse our selection of premium department store items, place your order, and look forward to the excitement of your free gift arriving alongside your purchase.
Shipping Policy
We will work hard to deliver items to you after receiving your orders and make sure they arrive safely. Delivery details will be provided in your confirmation email.In most cases, orders are processed within 2 days.Under special circumstances, it will be delayed as follows: When you place an order on Saturday, Sunday or public holidays, it will be delayed for 2 days..Normally, it needs 5-7 working days (Monday to Friday) without being affected by flight delay or other environmental factors..Because our shipping service is worldwide so the delivery times will depend on your location so it may need a few times and please wait patiently if you are in remote districts or countries.
1. Return & Exchange Policy
We only accept items purchased from roymall.com. If you purchase from our local distributors or other retailers, you cannot return them on our side.Final sales items or free gifts are not acceptable for a return.To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.After receiving return instructions from us, please package up your returned items and drop your package at the local post office or another courier. We will process your return or exchange item within 3-5 working days after we receive it. The refund will be processed and credited automatically to your original method of payment.No returns or exchanges can be accepted if the product was custom produced, including custom size, custom
color, or custom printed.Need more help, please contact us. service@roymall.com or Whatsapp: +8619359849471
2.Refund Policy
You'll get a full refund or 100% store credit after we receive the returned package and check it. The refund will be processed and credited automatically to your original method of payment.Please note that shipping costs and any duties or fees are not refundable. The extra shipping costs are non-refundable once the package has been shipped. You are responsible for paying these fees and we’re unable to waive or refund them, even if the order is returned back to us.Once we received and confirmed your returned item, we will send you an email to notify you that we have received your returned item. We will also notify you of the approval or rejection of your refund.If you have any problems regarding the refund process, please contact us. service@roymall.com or Whatsapp: +8619359849471
Description:
Geiger tube parameters: Technical parameters diameter: Φ10±0.5mm Total length: 90±2mm Starting voltage: < 350V Recommended operating voltage: 380V Minimum plateau length: 80V Maximum plateau slope: 10%/80V Extreme operating voltage: 550V The maximum count rate: 25 times / min Life: > 1 x 10^9 pulse Medium temperature: -40 ~ 55 ℃ Size:108x63x20mmInfos: click here!
Features: 1) 5V power supply, or 1.5V 3x battery; 1.2V 4x battery, current: 30mA - 12mA 2) for the detection of 20mR/h ~ 120mR/h of gamma rays and 100 ~ 1800 off variables / points / cm 2 of the soft beta ray. 3) sound and light alarm 4) interrupt the output interface, through this interface can be connected to the microcontroller and then displayed on the LCD.
5) Ardunio compatible 6) supports most of the Geiger tube: M4011, STS-5, SBM20, J305, etc. (the 330~600V operating voltage of the Geiger tube can be supported). 7) support the computer (PC) data acquisition, Matlab analysis and processing Detection of nuclear radiation work (copy the following link to the browser to watch): Http://v.youku.com/v_show/id_XNzI3MTU2NzQ0.html Customers using our Geiger counter to record the video: Http://v.youku.com/v_show/id_XOTE4ODIyNTIw.html
Compatible with : (recommended UNO R3 , or any other arbitrary with 5V and external interrupt INT) Internet can be downloaded: SPI example for Radiation Logger Logger Radiation can be used as the host computer software to build radiation monitoring station. Package included: 1 x Assembled Radiation system 1 x GM Tube 1 x Power supply cable 1 x Battery Holder (without batteries) 3 x Jumper Wires 4 x Nuts 1 x Acrylic cover
Go unlucky and received a unit from a lower quality batch. No support for the ICs, missing resistor meaning the power LED does not work, badly connected resistor, and even an inductance mounted SMD style because the leads were cut too short. The solder joints have not been heated enough and the solder did not penetrate in the vias. The board is pretty dirty (flux and solder residues that could short tracks).
Otherwise, the device works and is quite cheap. It comes with a lot of accessories which is useful.
Go unlucky and received a unit from a lower quality batch. No support for the ICs, missing resistor meaning the power LED does not work, badly connected resistor, and even an inductance mounted SMD style because the leads were cut too short. The solder joints have not been heated enough and the solder did not penetrate in the vias. The board is pretty dirty (flux and solder residues that could short tracks).
Otherwise, the device works and is quite cheap. It comes with a lot of accessories which is useful.
Go unlucky and received a unit from a lower quality batch. No support for the ICs, missing resistor meaning the power LED does not work, badly connected resistor, and even an inductance mounted SMD style because the leads were cut too short. The solder joints have not been heated enough and the solder did not penetrate in the vias. The board is pretty dirty (flux and solder residues that could short tracks).
Otherwise, the device works and is quite cheap. It comes with a lot of accessories which is useful.
This is a good geiger counter at cheaper price, perfect to connect with a ESP or arduino module to make a portable radioactivity meter. The board show the particle detected via a buzzer a red led and via TTL pulse output. The module can be connected to battery pack (primary or NI-Mh cell) or directly powered from an Arduino or ESP module via 5V pin. Useful to continuos meter the enviromental radioactivity.
A good Geiger counter +++
Cheaper geiger counter
This is a good geiger counter at cheaper price, perfect to connect with a ESP or arduino module to make a portable radioactivity meter. The board show the particle detected via a buzzer a red led and via TTL pulse output. The module can be connected to battery pack (primary or NI-Mh cell) or directly powered from an Arduino or ESP module via 5V pin. Useful to continuos meter the enviromental radioactivity.
A good Geiger counter +++
Cheaper geiger counter
This is a good geiger counter at cheaper price, perfect to connect with a ESP or arduino module to make a portable radioactivity meter. The board show the particle detected via a buzzer a red led and via TTL pulse output. The module can be connected to battery pack (primary or NI-Mh cell) or directly powered from an Arduino or ESP module via 5V pin. Useful to continuos meter the enviromental radioactivity.
A good Geiger counter +++
Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.
Open construction, so not watertight in the slightest. To mute the on-board speaker, remove jumper plug J1 which is wired in series with the speaker.
Open construction, so not watertight in the slightest. To mute the on-board speaker, remove jumper plug J1 which is wired in series with the speaker.
Answered by VE1BLL on 17/11/2019Helpful (0)
0
Q:
(Duplicate) The VIN output gives off constant reading that does not change when the counter is triggered. The light and sound device go off, but VIN stays at a constant value. When using the analog pins on the arduino, it is a constant 1023 reading, with no variation. This still occurs when covered and hidden in the dark. <br/><br/>To confirm, the only issue is the VIN output. The light and sound device output
(Duplicate) The VIN output gives off constant reading that does not change when the counter is triggered. The light and sound device go off, but VIN stays at a constant value. When using the analog pins on the arduino, it is a constant 1023 reading, with no variation. This still occurs when covered and hidden in the dark. <br/><br/>To confirm, the only issue is the VIN output. The light and sound device output
VIN normally stand for the input voltage, straight from the battery or power circuit. It's expected to not vary at all. You need to find an ouput as a signal.
VIN normally stand for the input voltage, straight from the battery or power circuit. It's expected to not vary at all. You need to find an ouput as a signal.
Answered by mlune on 02/02/2023Helpful (0)
0
Q:
Hello, I purchased two counters to make a muon detector. They both arrived safely and seem to work, however one of the counters sometimes just turns on constantly and the counter and light stay on and the noise is constant screech. Any ideas why? Thanks.
Hello, I purchased two counters to make a muon detector. They both arrived safely and seem to work, however one of the counters sometimes just turns on constantly and the counter and light stay on and the noise is constant screech. Any ideas why? Thanks.
I would get a magnifier and check the soldered joints, look for shorts, loose connections or dull looking dry joints. If any issues are seen, you will probably need to do some resoldering, hopefully that solves it for you.
I would get a magnifier and check the soldered joints, look for shorts, loose connections or dull looking dry joints. If any issues are seen, you will probably need to do some resoldering, hopefully that solves it for you.
Answered by ivanbrown001 on 25/06/2021Helpful (0)
0
Q:
My assembled Geiger counter just arrived. The power light comes on, the high voltage appears to be correct, and touching the - connector of the tube with a probe does cause beeping and D23 to light briefly, but it is silent when left alone. Is there a way to test the tube? The tube seems intact, but I don't know what I'm looking for. I believe it should detect some background radiation, perhaps a click every few seconds?
My assembled Geiger counter just arrived. The power light comes on, the high voltage appears to be correct, and touching the - connector of the tube with a probe does cause beeping and D23 to light briefly, but it is silent when left alone. Is there a way to test the tube? The tube seems intact, but I don't know what I'm looking for. I believe it should detect some background radiation, perhaps a click every few seconds?
Can this output a lower voltage than 330? Can the voltage output be regulated based on the input? for example, 5v suppy will make unit output 600v, but 1v supply will make it output 330 (or lowest)?
Can this output a lower voltage than 330? Can the voltage output be regulated based on the input? for example, 5v suppy will make unit output 600v, but 1v supply will make it output 330 (or lowest)?
Mostly gamma rays and beta particles.This type of GM-tube isn't designed for alpha radiation.
Mostly gamma rays and beta particles.This type of GM-tube isn't designed for alpha radiation.
Answered by plamenbekyarov on 20/04/2020Helpful (0)
0
Q:
My Geiger module generates series of false clicks. For example it works normally for 20 seconds and then generates 15 false click in 1 second. Normal background radiation is 12-20 clicks per minute. Can I repair the module or do something?
My Geiger module generates series of false clicks. For example it works normally for 20 seconds and then generates 15 false click in 1 second. Normal background radiation is 12-20 clicks per minute. Can I repair the module or do something?
IF it’s recurring at regular 1min intervals, perhaps it may proof useful to check the condensators soldering to the PCB and -or- possible influence by near short circuiting with other parts. I.e. bend them to another position. IF this does not work, just to make sure, move the Geiger teller to another location a couple of km’s away and check again. You never know if it accidentally does register correct.... Than you have an interesting case to solve =:)
IF it’s recurring at regular 1min intervals, perhaps it may proof useful to check the condensators soldering to the PCB and -or- possible influence by near short circuiting with other parts. I.e. bend them to another position. IF this does not work, just to make sure, move the Geiger teller to another location a couple of km’s away and check again. You never know if it accidentally does register correct.... Than you have an interesting case to solve =:)
Answered by mdc10.50 on 07/02/2020Helpful (0)
0
Q:
Excuse me, but the geiger tube of the kit is an J305 or M4011?
Excuse me, but the geiger tube of the kit is an J305 or M4011?
pretty Strange as the Files in the description are stating about a M4011 and I can't find anything about a J305 Datasheet which is mildly annoying imma just proceed with the Idea of the J305 and M4011 being built exactly the Same way
pretty Strange as the Files in the description are stating about a M4011 and I can't find anything about a J305 Datasheet which is mildly annoying imma just proceed with the Idea of the J305 and M4011 being built exactly the Same way
Answered by PanickingLynx on 16/06/2020Helpful (0)
0
Q:
How do I get the data out of this device? Any manuals?
How do I get the data out of this device? Any manuals?
A starting point... Search with obvious search terms plus cooking-hacks.
A starting point... Search with obvious search terms plus cooking-hacks.
Answered by VE1BLL on 17/11/2019Helpful (0)
0
Q:
Bonjour,
mon kit est bien arrivé dans les délais. Merci beaucoup je suis trés heureux.
Serait-il possible d'avoir le schéma électronique du circuit ? Une documentation ?
Un programme pour arduino ? une information, une aide?
merci.
*****
Bonjour,
mon kit est bien arrivé dans les délais. Merci beaucoup je suis trés heureux.
Serait-il possible d'avoir le schéma électronique du circuit ? Une documentation ?
Un programme pour arduino ? une information, une aide?
merci.
*****
Instructions: 1. Download the arduino IDE 2. Download the USB chip driver 3. Plug in the UNO development board and the driver will be installed automatically. 4. Select the board in the die UNO 5. Select the COM port, this can be queried in my computer, just the port inside your uno development board 6. It is best to choose the routine program that comes with arduino and burn it into it.
Instructions: 1. Download the arduino IDE 2. Download the USB chip driver 3. Plug in the UNO development board and the driver will be installed automatically. 4. Select the board in the die UNO 5. Select the COM port, this can be queried in my computer, just the port inside your uno development board 6. It is best to choose the routine program that comes with arduino and burn it into it.
Answered by Sniftywas on 05/06/2019Helpful (0)
0
Q:
I notice there is a jumper called "Test". Should the jumper be installed or not for normal operation?
I notice there is a jumper called "Test". Should the jumper be installed or not for normal operation?
Jumper J4 TEST apparently doesn't matter. Removing it would disconnect a series of 10M resistors leading to a test point J2 that is open circuit anyway. Mine is in place and works fine. See the schematic, linked in Description.
Jumper J4 TEST apparently doesn't matter. Removing it would disconnect a series of 10M resistors leading to a test point J2 that is open circuit anyway. Mine is in place and works fine. See the schematic, linked in Description.
Answered by VE1BLL on 17/11/2019Helpful (0)
0
Q:
what is the output?do we need to add lcd screen to display it?
what is the output?do we need to add lcd screen to display it?
Creo recordar que yo use los pines de salida de este circuito y lo conect a los pines de entrada de mi arduino nano (clon). En mi caso, utilic un proyecto ya existente que indicaba cmo tena que conectar los pines. An as, yo no me fiara mucho de las indicaciones de este aparato... como juguete est bien, pero no me fiara yo de las lecturas para algo serio
Us
Answered by barmale4 on 26/07/2024Helpful (0)
0
Q:
The VIN output gives off constant reading that does not change when the counter is triggered. The light and sound device go off, but VIN stays at a constant value. When using the analog pins on the arduino, it is a constant 1023 reading, with no variation.
The VIN output gives off constant reading that does not change when the counter is triggered. The light and sound device go off, but VIN stays at a constant value. When using the analog pins on the arduino, it is a constant 1023 reading, with no variation.
I want to use it together with an esp8266 microprocesser, do you know if it is compatible? What do you mean with: "UNO R3 recommended, or any other arbitrary with 5V and external interrupt INT", What is 'external interrupt INT'?
I want to use it together with an esp8266 microprocesser, do you know if it is compatible? What do you mean with: "UNO R3 recommended, or any other arbitrary with 5V and external interrupt INT", What is 'external interrupt INT'?
I have the intention to measure gamma environmental radiation, in this case I should use the geiger tube SBM-19, you can tell if it is compatible. Does Vc sell it with SBM-19 or without the Geiger tube? Can you tell the time of each reading?
Eu tenho a intensão de medir radiação Gama Ambiental, neste caso deverei usar o geiger tube SBM-19, você sabe dizer se ele é compatível. Vc vende ele com SBM-19 ou sem o tubo Geiger? Sabe dizer o tempo de cada leitura?
I would say you can change the geiger tube as long it have same working voltage as this unit, or you can wrap this tube in some metal foil so only particles with higher energy levels do get counted and alfa particles get blocked by metal foil
I would say you can change the geiger tube as long it have same working voltage as this unit, or you can wrap this tube in some metal foil so only particles with higher energy levels do get counted and alfa particles get blocked by metal foil
Answered by PatracPatra on 27/09/2021Helpful (0)
0
Q:
Can you run it from a 6V battery? Or a 12V car battery?
Can you run it from a 6V battery? Or a 12V car battery?