* Estimated delivery times start from the date of shipment, excluding processing time.
* Actual delivery times may vary due to holidays, weather conditions, or customs delays.
Return items will be accepted within 40 days when is the date of receiving the goods. Customized items cannot be returned or exchanged. Items bought with an e-gift card are exchangeable only; refunds are not applicable.
Free Gift
Welcome to Roymall, your professional website for purchasing premium department store gifts. We highly value and appreciate your support, and we want to express our gratitude by adding an extra touch of excitement to your purchases. When you shop with us, you not only get to enjoy high-quality products that enhance your lifestyle, but you'll also receive an exclusive free gift with every order you place. Ready to explore our collection and find your perfect gifts? Browse our selection of premium department store items, place your order, and look forward to the excitement of your free gift arriving alongside your purchase.
Shipping Policy
We will work hard to deliver items to you after receiving your orders and make sure they arrive safely. Delivery details will be provided in your confirmation email.In most cases, orders are processed within 2 days.Under special circumstances, it will be delayed as follows: When you place an order on Saturday, Sunday or public holidays, it will be delayed for 2 days..Normally, it needs 5-7 working days (Monday to Friday) without being affected by flight delay or other environmental factors..Because our shipping service is worldwide so the delivery times will depend on your location so it may need a few times and please wait patiently if you are in remote districts or countries.
1. Return & Exchange Policy
We only accept items purchased from roymall.com. If you purchase from our local distributors or other retailers, you cannot return them on our side.Final sales items or free gifts are not acceptable for a return.To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.After receiving return instructions from us, please package up your returned items and drop your package at the local post office or another courier. We will process your return or exchange item within 3-5 working days after we receive it. The refund will be processed and credited automatically to your original method of payment.No returns or exchanges can be accepted if the product was custom produced, including custom size, custom
color, or custom printed.Need more help, please contact us. service@roymall.com or Whatsapp: +8619359849471
2.Refund Policy
You'll get a full refund or 100% store credit after we receive the returned package and check it. The refund will be processed and credited automatically to your original method of payment.Please note that shipping costs and any duties or fees are not refundable. The extra shipping costs are non-refundable once the package has been shipped. You are responsible for paying these fees and we’re unable to waive or refund them, even if the order is returned back to us.Once we received and confirmed your returned item, we will send you an email to notify you that we have received your returned item. We will also notify you of the approval or rejection of your refund.If you have any problems regarding the refund process, please contact us. service@roymall.com or Whatsapp: +8619359849471
NOTE:
The system can store for 15pcs of remotes, if the remote get more than 15pcs, the initial remote control will be lost.
Feature:
Wiring type: fixed terminal
Standby current: <5MA
Input power: DC10V-14V
RF frequency: 433Mhz
Receive sensitivity: >97dbm
Output terminal: NO, NC, COM
RF working mode: Superheterodyne
Decoding mode: MCU software decoding
Transmitting distance: >100m ( open space)
Support remote type: Learning code, Fixed code(Rolling code can be design)
Working mode: Momentary, Toggle, Latching Time delay (5s, 10s, 15s )
About Working mode:
- Momentary: Push the remote button, the relay connects, release the remote button, the relay disconnects.
- Toggle: Push once the remote button, the relay connects, push twice the remote button, the relay disconnects.
- Latching: Push the remote button A, the relay connects, push the remote button B, the relay dis-connect.
- Time delay mode: Push the remote control button, the relay connects, from when releasing the remote button, after 5s or 10s or 15s, the relay disconnect automatically.
Clearing the code:
Push the learning button on the receivers for 8 times, the codes will be cleaned.
After clearing the code, all the remote control cannot work anymore.
1. Learning the code: (Momentary)
Push the learning key on the receiver once time, it comes into the momentary setting mode.
Wait for a moment, the LED will be off , it comes into learning state.
Push the remote button, LED indicator on the receiver board will flash then come off.
After 3 seconds, the LED indicator will be on again, learning successfully.
2. Learning the code: ( Toggle )
Push the learning key on the receiver twice, it comes into toggle setting mode
Wait for a moment, the LED will be off, it comes into learning state.
Push the remote button, LED indicator on the receiver board will flash then come off.
After 3 seconds , the LED indicator will be on again , learning successfully.
3. Learning the code: ( Latching )
Note: When you choose for latching mode, in order to learn more remote control, you need to learn two different button, the first time learned is for "ON", the second time learned for "OFF".
For example: button A = ON , button B = OFF
Push the learning key on the receiver triple time, it comes into latching mode.
Wait for a moment, the LED indicator on the receiver board will flash then come off.
Push the remote button A.
LED flash for 5 times.
Push the remote button B.
LED flash for 5 times.
After 3 seconds, the LED indicator will be on again , learning successfully.
A = ON , B = OFF.
Package included:
2 x Remote Control Transmitters (including battery)
2. Due to the difference between different monitors, the picture may not reflect the actual color of the item. We guarantee the style is the same as shown in the picture.
Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.
para uma pequena acção é possível ligar e desligar para ficar aberto por tempo indeterminado queima
para uma pequena acção é possível ligar e desligar para ficar aberto por tempo indeterminado queima
Answered by BG184816171 on 10/02/2022Helpful (0)
0
Q:
Hi, I purchased two of these units and installed both for friend's garage doors. Both friends have told me that they operate 'on their own accord' with no remote being used????? I decommissioned from the garage doors and have set them up on test, connected to a buzzer so each time the relay switches it operates the buzzer and can confirm that they operate on their own, intermittently and frequently, ??? Any assistance would be appreciated otherwise I can NOT recommend these to anyone if you want it to reliably operate.
Hi, I purchased two of these units and installed both for friend's garage doors. Both friends have told me that they operate 'on their own accord' with no remote being used????? I decommissioned from the garage doors and have set them up on test, connected to a buzzer so each time the relay switches it operates the buzzer and can confirm that they operate on their own, intermittently and frequently, ??? Any assistance would be appreciated otherwise I can NOT recommend these to anyone if you want it to reliably operate.
I have exactly the same random trigger problem. The relay operates by itself intermittently for a micro-second. Has anyone tried isolating the keys to see if this is an issue with the receiver or the key fobs creating random bursts?
I have exactly the same random trigger problem. The relay operates by itself intermittently for a micro-second. Has anyone tried isolating the keys to see if this is an issue with the receiver or the key fobs creating random bursts?
433Mhz is the frequency of the oscillator. It is a quartz with a filter, but it is nothing like SW. So you cannot simply reprogram the circuit.
However, if you can change the quartz, the IC and the filter, you may obtain an 868.3 Mhz receiver. The key will still be available in 433 Mhz as they are built, so you will need new transmitters.
It is far easier to find directly an 868.3 Mhz transmitter-receiver units.
433MHis the frequency of the oscillator. It is a qartz, and filter, it is notva SW. So you cannot simply reprogram the circuit.
However, if you change qartz, IC and filter, you may obtain a 8683 Mhz receiver. The key will still be available in 433 Mhz az they are built, so you will ned new transmiters.
Basically it is far more easy to find directly a 868.3 Mhz transmiter - receiver units.
Answered by Paul on 14/03/2022Helpful (0)
0
Q:
It`s not possible for me to activate the Momentum Mode.<br/>I can only switch on/off with the same button or on/off with the two different buttons.<br/>But i need specific the Momentum Mode, wtahts wrong?<br/>There are also 3 Pins with a 2pole bridge, i can set this left or right, no changesjQuery111305012531998043823_1702484348395<br/><br/>Need help please?
It`s not possible for me to activate the Momentum Mode.<br/>I can only switch on/off with the same button or on/off with the two different buttons.<br/>But i need specific the Momentum Mode, wtahts wrong?<br/>There are also 3 Pins with a 2pole bridge, i can set this left or right, no changesjQuery111305012531998043823_1702484348395<br/><br/>Need help please?
It is set up for latching as it does latch for a period of time, the problem is, Latching Switch randomly changes state. There are a few people asking about this on here. It is a known problem so do you have a fix?
It is set up for latching as it does latch for a period of time, the problem is, Latching Switch randomly changes state. There are a few people asking about this on here. It is a known problem so do you have a fix?
J'ai installé le boitier pour remplacer la commande existante sur un moteur Marantec CONFORT 150.les télecommandes fonctionnent correctement mais toutes les 15 mn environ, le boitier envoie un signal et ouvre ou ferme le portail et je ne comprend pas pourquoiPouvez-vous me donner une explicationMerci
J'ai installé le boitier pour remplacer la commande existante sur un moteur Marantec CONFORT 150.les télecommandes fonctionnent correctement mais toutes les 15 mn environ, le boitier envoie un signal et ouvre ou ferme le portail et je ne comprend pas pourquoiPouvez-vous me donner une explicationMerci
Hello has to be switched over minus or also goes over Plus. I want button A on and button B off ... What pin assignment ... Need a tutorial
Hallo muss über minus geschaltet werden oder geht auch über Plus. Ich möchte Knopf A an und Knopf B Aus ... welche Pin belegung ... Brauche eine Anleitung
Are these units secure, I have installed one onto a Bangood DC 12V 150kg/330lb Holding Force Electromagnetic Door Lock which sporadically operates without the use of the remote. Regards Ian Knox
Are these units secure, I have installed one onto a Bangood DC 12V 150kg/330lb Holding Force Electromagnetic Door Lock which sporadically operates without the use of the remote. Regards Ian Knox